Product Description

Salient Features of Large Flow All in one Low Pressure Coolant Pump:

  • Pump: Impeller
  • Motor: 1500~3700 W/AC
  • Flow rate: 150~300 /min
  • Total pump head: 40~65 m

Model Numbering System

Motor capacity 1500 : 1.5kW
3700 : 3.7kW
Motor type AC : AC 200/200/220/230 V 50/60/60/60 Hz
3 phase electric induction motor (IE3) with CE marking

I155・I305 is not applicable to 60Hz

Flow rate 50Hz I155 : Impeller pump (5 stages/150l)
60Hz I152 : Impeller pump (2 stages/150l)
50Hz I305 : Impeller pump (5 stages/300l)
60Hz I302 : Impeller pump (2 stages/300l)
Filtering method C : cyclone type

Specification :

Item Model

Motor capacity (kW)

Flow Rate (& / min)

Total pum head (m)

Approximate weight

YTH1500AC-I155C (50Hz) 1.5 150 55 43
YTH1500AC-I152C (60Hz) 40
YTH3700AC-I305C (50Hz) 3.7 300 55 70
YTH3700AC-I302C (60Hz) 40 69

Large flow All-in-one Low-pressure coolant pump

This is a YTH corresponding to large flow & low pressure with cyclone filter. YTH-CI enables users to be free from troubles and filter maintenance around a coolant tank due to automatic clean-up unit by cyclone filter.

  • Total pump head 40~65 m
  • Maximum flow rate :
    • CI 15 x C 150 l /min
    • CI 30 x C 300 l /min
  • No suction filter is required (continuous operation only)
  • Applications to various types of coolant tanks

Plan-A Application to coolant tank + isolated clean tank

YTH-CI transfers filtered coolant from a coolant tank to an isolated clean tank. Filtered coolant is supplied to machining centers by High-Medium pressure coolant supply pumps. Chips and contaminants are pushed out from YTH-CI and collected by magnet separator or sedimentation tank.

Plan-B Application to integrated coolant tank and clean tank

YTH-CI can totally clean up a coolant tank by circulation flow. At the same time, YTH-CI also automatically backwash plate strainers between a coolant tank and a clean tank by suction of dirty coolant, which reduces maintenance work for backwash plate dramatically.

Plan-C Application to single coolant tank (without clean tank)

YTH-CI supplies filtered coolant to nozzles in a machinery tool. When the machinery tool stops metal cutting operation, YTH-CI automatically switches to cleaning of a coolant tank by circulation flow.

YTH-CI – the All in one coolant unit

  • Coolant supply Filtered coolant is supplied to avoid clogging and damages to surface of work piece
  • Chips and contaminants collection Chips and contaminants in a coolant tank is automatically collected to reduce maintenance work dramatically
  • Agitation of coolant Making circulation flow in a coolant tank delays fermentation of coolant, which results in less odor around the coolant tank

Unique reversed cyclone system enables to separate clean coolant and contaminants. Contaminants are pushed up through side surface of cyclone filter by centrifugal force and discharged. Clean coolant are collected to center of cyclone filter and boosted up by multiple-stage impellor pump.

Impeller Pump

  • Multiple-stage impellers are used for YTH-CI to boost up and supply a large quantity of coolant
  • Compatible types of fluid
  • Water-soluble coolant fluid
  • Not for Water-insoluble coolant fluid, lubricant oil or fuel oil
  • Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils

Compatible types of chips :

Material

Iron

Casting

Aluminium

Copper

Compatibility

Excellent

Excellent

Good

Excellent

Please contact us for the use of High Silicon Aluminum

Filtering Performance :

Suction Strainer 3mm (Solids larger than this must be removed in the tank)
Filter 50µm: 95% (specific gravity 2.7)
100µm: 99% (specific gravity 2.7)

 

Series name C SERIES CT
(Specification : Double cyclone filter + TrochoidTM pump)
C SERIES CI
(Specification: Cyclone filter + Impeller pump)
Specifications for pump proper
Pump model T208
50Hz / 60Hz
T216
50Hz / 60Hz
I155 I152 I305 I302
Flow rate (l /min) 12.0 / 14.4 24.0 / 28.8 150 (Maximum) 300 (Maximum)
Compatible fluid Water-soluble coolant fluid
Maximum allowable viscosity (mm2/s)
(Filtering performance)
22 2
Liquid temperature range (oC) -5 ~ 60
Rotational speed (r/min) 1500 / 1800 3000 3600 3000 3600
Maximum pressure (MPa) 2.0
Total pump head (m) 55 40 65 45
Filter type Cyclone x 2 stages Cyclone x 1 stage
Filtering performance 100µm: 99.9%-50µm: 95% (Silica sand: specific gravity2.7)
Contaminant drain port flow rate (l/min) 30~40
(Pressure 0.02MPa)
20~35
(Pressure 0.02MPa)
25~40
(Pressure 0.02MPa)
45~60
(Pressure 0.02MPa)
50~70
(Pressure 0.02MPa)
Remarks Install a plate filter of #18 or finer mesh on the suction end of the tank.
Painted color of the pump section Flat black (Approximately Munsell N1.0)
Approximate weight (kg) 16 23 34 33
Relief valve specifications
Type External return type
Relief pressure setting (MPa) 2.0 / 1.5
Motor specifications*1
Model No. 750A3 1500A3 1500AC 3700AC
Specifications 3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration
Output (kW) 0.75 1.5 1.5 3.7
Voltage (V) 200/200/220/230 200/200/220/230 200/200/220/230 200/200/220/230
Frequency (Hz) 50/60/60/60 50/60/60/60 50/60/60/60 50/60/60/60
Rotational speed (r/min) 1440/1730/1745/1745 1445/1740/1750/1755 2890/3460/3485/3495 2910/3490/3515/3525
Rating S1
Current (A) 3.80/3.40/3.40/3.40 6.80/6.40/6.00/6.00 6.00/5.80/5.40/5.20 13.6/13.2/12.2/11.8
Number of phases 3
Number of poles 4P 2P
Insulation class F
Approximate weight (kg) 18 23 20 36
Protection rating IP55
Efficiency class IE3
Compliance CE 0