NOP Coolant Unit CT

NOP Coolant Unit CT

Product Code : CT
Product Description

Backed by more the 02 years of dedication, we offer the finest NOP Coolant Unit YTH Pumps to clients. Made up of top-notch stainless steel and other basic material, this is acknowledge for hassle-free functionality, less maintenance needs, wear & tear resistance and long lasting nature. We offer the NOP Coolant Unit YTH Pumps in varied weights, capacity and other specifications at moderate rates. In addition, we deliver these pumps in protective packaging to clients within promised time frame.

Salient Features :

  • Pump: TrochoidTM
  • Motor: 750~1500 W/AC
  • Flow rate: 12~28.8 /min
  • Maximum Pressure: 2.0 MPa

Double-cyclone filter

  • Two layers of double cyclones (one large cyclone and six small cyclones) remove chips from the coolant fluid.

TrochoidTM pump/ 2.0 MPa, 1.5 MPa

  • 1.5A rotor turning in a trochoidal curve generates pressure to suck and discharge fluid. This is an extremely efficient self-priming pump.

Compatible with the TAZUNATM fluid control system (software)

  • TAZUNATM reduces the electric power cost further by approximately 20%.
  • TM The pressure and flow rate are automatically adjusted.

Model Numbering System

Motor Capacity 750 : 0.75 kW
1500 : 1.5 kW
Motor Typed Standard motor A3 AC 200/200/220/230 V
50/60/60/60 Hz
3 phase electric induction motor(IE3) with CE marking
Local

Motor

AE: supplied by NOP Deutschl and (Germany)
AF: supplied by NOP Taiwan
AJ: supplied by NOP Asia (China)
AK: supplied by NOP India

For further details about the local motor, please contact to our overseas branch or subsidiaries.

Rotor Capacity

T208: Trochoid TM pump, 8cc / rev
T206: Trochoid TM pump, 16cc / rev
Filtering method C : Double-cyclone type
Relief Valve VD : External return type
Relief Pressure setting 20 : 2.0 MPa
15 : 1.5 MPa

Specification:

Item Model Motor Capacity (kW) Flow Rate (& min) 50 Hz/ 60 Hz Maximum Pressure (MPa) Approximate weight (kg)
YTH750A3-T208CVD * 0.75 12.0 / 14.4 2.0 34
YTH1500A3-T216CVD * 1.5 24.0 / 28.2 39

Dimensional :

Item Model L B C W Q H M D I(o) TB
YTH750A3-T208CVD * 599.7 235.7 206.7 175.7 20 364 253.5 170 30 151
YTH1500A3-T216CVD * 639.2 255.7 226.7 195.7 40 383.5 273 202 45 168

For further details about the local motor, please contact to our overseas branch or subsidiaries.

Rotor Capacity

T208: Trochoid TM pump, 8cc / rev
T206: Trochoid TM pump, 16cc / rev
Filtering method C : Double-cyclone type
Relief Valve VD : External return type
Relief Pressure setting 20 : 2.0 MPa
15 : 1.5 MPa

Specification:

Item Model

Motor Capacity (kW)

Flow Rate (& min) 50 Hz/ 60 Hz

Maximum Pressure (MPa)

Approximate weight (kg)

YTH750A3-T208CVD * 0.75 12.0 / 14.4 2.0 34
YTH1500A3-T216CVD * 1.5 24.0 / 28.2 39

Dimensional :

Item Model

L

B

C

W

Q

H

M

D

I(o)

TB

YTH750A3-T208CVD * 599.7 235.7 206.7 175.7 20 364 253.5 170 30 151
YTH1500A3-T216CVD * 639.2 255.7 226.7 195.7 40 383.5 273 202 45 168

World’s First – All-in-one, Medium-pressure Coolant Pump

This is a basic YTH model consolidating a large coolant system into one unit. Simply replace a conventional medium-pressure pump with YTH-CT to reduce the occupied space to 1/20th by volume. The saved space expands the available plant space, resulting in a higher production efficiency.

  • Maximum operating pressure: 2.0 MPa
  • Maximum flow rate: 28.8 liters/min
  • No suction filter is required
  • No clean tank is required
  • Applicable only to continuous running (intermittent running is not applicable)
  • No transfer pump is required on the coolant tank end
  • No plumbing is required to interconnect various components

Double-cyclone Filter

A proprietary double-cyclone system removes chips. The first cyclone removes larger debris, while the second cyclones remove smaller particles. The line-filter cleaning cycle is extended by 24 times.

Chips larger than 20m in size is removed (when using water-soluble coolant fluid).

Compatible types of chips :

Material

Iron

Casting

Aluminium

Copper

Compatibility

Excellent

Excellent

Good

Excellent

  • No liquid containing abrasive stone/grain is allowed
  • Please contact us for the use of High Silicon Aluminum

Filtering Performance :

Suction Strainer 3mm (Solids larger than this must be removed in the tank)
Filter 50 m: 95% (specific gravity 2.7)
100 m: 99% (specific gravity 2.7)

High-efficiency TrochoidTM Pump

YTH-CT uses a TrochoidTM pump which excels in fluid control efficiency. The double-cyclone system sorts out chips and enables direct connection to the coolant tank.

Compatible types of fluid

  • Water-soluble coolant fluid
  • Not for water-insoluble coolant fluid, lubricant oil or fuel oil
  • Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils
  • Relief valve is built into the unit.

Huge Energy Saving Effect Reduces Utility Costs

The use of YTH-CT results in huge energy savings over the conventional centrifugal pumps. The electric power cost is greatly reduced.

  • Operating cycle: total 80 seconds cycle
    • Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
    • Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
  • The calculation is based on operation 8hours/day, 365days/year, and the electric power billed at  20/kWh.

Results may differ according to the conventional pump specifications and the machining conditions reference data

Series name C SERIES CT
(Specification : Double cyclone filter + TrochoidTM pump)
C SERIES CI
(Specification: Cyc
lone filter + Impeller pump)
Specifications for pump proper
Pump model T208
50Hz / 60Hz
T216
50Hz / 60Hz
I155 I152 I305 I302
Flow rate (l /min) 12.0 / 14.4 24.0 / 28.8 150 (Maximum) 300 (Maximum)
Compatible fluid Water-soluble coolant fluid
Maximum allowable viscosity (mm2/s)
(Filtering performance)
22 2
Liquid temperature range (oC) -5 -60
Rotational speed (r/min) 1500 / 1800 3000 3600 3000 3600
Maximum pressure (MPa) 2.0
Total pump head (m) 55 40 65 45
Filter type Cyclone x 2 stages Cyclone x 1 stage
Filtering performance 100m: 99.9~ 50 m: 95% (Silica sand: specific gravity2.7)
Contaminant drain port flow rate (l/min) 30~40
(Pressure 0.02MPa)
20~35
(Pressure 0.02MPa)
25~40
(Pressure 0.02MPa)
45~60
(Pressure 0.02MPa)
50~70
(Pressure 0.02MPa)
Remarks Install a plate filter of #18 or finer mesh on the suction end of the tank.
Painted color of the pump section Flat black (Approximately Munsell N1.0)
Approximate weight (kg) 16 23 34 33
Relief valve specifications
Type External return type
Relief pressure setting (MPa) 2.0 / 1.5
Motor specifications*1
Model No. 750A3 1500A3 1500AC 3700AC
Specifications 3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration
Output (kW) 0.75 1.5 1.5 3.7
Voltage (V) 200/200/220/230 200/200/220/230 200/200/220/230 200/200/220/230
Frequency (Hz) 50/60/60/60 50/60/60/60 50/60/60/60 50/60/60/60
Rotational speed (r/min) 1440/1730/1745/1745 1445/1740/1750/1755 2890/3460/3485/3495 2910/3490/3515/3525
Rating S1
Current (A) 3.80/3.40/3.40/3.40 6.80/6.40/6.00/6.00 6.00/5.80/5.40/5.20 13.6/13.2/12.2/11.8
Number of phases 3
Number of poles 4P 2P
Insulation class F
Approximate weight (kg) 18 23 20 36
Protection rating IP55
Efficiency class IE3
Compliance CE 0