NOP Coolant Unit CT
Backed by more the 02 years of dedication, we offer the finest NOP Coolant Unit YTH Pumps to clients. Made up of top-notch stainless steel and other basic material, this is acknowledge for hassle-free functionality, less maintenance needs, wear & tear resistance and long lasting nature. We offer the NOP Coolant Unit YTH Pumps in varied weights, capacity and other specifications at moderate rates. In addition, we deliver these pumps in protective packaging to clients within promised time frame.
Salient Features :
- Pump: TrochoidTM
- Motor: 750~1500 W/AC
- Flow rate: 12~28.8 /min
- Maximum Pressure: 2.0 MPa
Double-cyclone filter
- Two layers of double cyclones (one large cyclone and six small cyclones) remove chips from the coolant fluid.
TrochoidTM pump/ 2.0 MPa, 1.5 MPa
- 1.5A rotor turning in a trochoidal curve generates pressure to suck and discharge fluid. This is an extremely efficient self-priming pump.
Compatible with the TAZUNATM fluid control system (software)
- TAZUNATM reduces the electric power cost further by approximately 20%.
- TM The pressure and flow rate are automatically adjusted.
Model Numbering System
Motor Capacity | 750 : 0.75 kW | |
1500 : 1.5 kW | ||
Motor Typed | Standard motor | A3 AC 200/200/220/230 V 50/60/60/60 Hz 3 phase electric induction motor(IE3) with CE marking |
Local
Motor |
AE: supplied by NOP Deutschl and (Germany) AF: supplied by NOP Taiwan AJ: supplied by NOP Asia (China) AK: supplied by NOP India |
For further details about the local motor, please contact to our overseas branch or subsidiaries.
Rotor Capacity
T208: Trochoid TM pump, 8cc / rev | |
T206: Trochoid TM pump, 16cc / rev | |
Filtering method | C : Double-cyclone type |
Relief Valve | VD : External return type |
Relief Pressure setting | 20 : 2.0 MPa |
15 : 1.5 MPa |
Specification:
Item Model | Motor Capacity (kW) | Flow Rate (& min) 50 Hz/ 60 Hz | Maximum Pressure (MPa) | Approximate weight (kg) |
YTH750A3-T208CVD * | 0.75 | 12.0 / 14.4 | 2.0 | 34 |
YTH1500A3-T216CVD * | 1.5 | 24.0 / 28.2 | 39 |
Dimensional :
Item Model | L | B | C | W | Q | H | M | D | I(o) | TB |
YTH750A3-T208CVD * | 599.7 | 235.7 | 206.7 | 175.7 | 20 | 364 | 253.5 | 170 | 30 | 151 |
YTH1500A3-T216CVD * | 639.2 | 255.7 | 226.7 | 195.7 | 40 | 383.5 | 273 | 202 | 45 | 168 |
For further details about the local motor, please contact to our overseas branch or subsidiaries.
Rotor Capacity
T208: Trochoid TM pump, 8cc / rev | |
T206: Trochoid TM pump, 16cc / rev | |
Filtering method | C : Double-cyclone type |
Relief Valve | VD : External return type |
Relief Pressure setting | 20 : 2.0 MPa |
15 : 1.5 MPa |
Specification:
Item Model |
Motor Capacity (kW) |
Flow Rate (& min) 50 Hz/ 60 Hz |
Maximum Pressure (MPa) |
Approximate weight (kg) |
YTH750A3-T208CVD * | 0.75 | 12.0 / 14.4 | 2.0 | 34 |
YTH1500A3-T216CVD * | 1.5 | 24.0 / 28.2 | 39 |
Dimensional :
Item Model |
L |
B |
C |
W |
Q |
H |
M |
D |
I(o) |
TB |
YTH750A3-T208CVD * | 599.7 | 235.7 | 206.7 | 175.7 | 20 | 364 | 253.5 | 170 | 30 | 151 |
YTH1500A3-T216CVD * | 639.2 | 255.7 | 226.7 | 195.7 | 40 | 383.5 | 273 | 202 | 45 | 168 |
World’s First – All-in-one, Medium-pressure Coolant Pump
This is a basic YTH model consolidating a large coolant system into one unit. Simply replace a conventional medium-pressure pump with YTH-CT to reduce the occupied space to 1/20th by volume. The saved space expands the available plant space, resulting in a higher production efficiency.
- Maximum operating pressure: 2.0 MPa
- Maximum flow rate: 28.8 liters/min
- No suction filter is required
- No clean tank is required
- Applicable only to continuous running (intermittent running is not applicable)
- No transfer pump is required on the coolant tank end
- No plumbing is required to interconnect various components
Double-cyclone Filter
A proprietary double-cyclone system removes chips. The first cyclone removes larger debris, while the second cyclones remove smaller particles. The line-filter cleaning cycle is extended by 24 times.
Chips larger than 20m in size is removed (when using water-soluble coolant fluid).
Compatible types of chips :
Material |
Iron |
Casting |
Aluminium |
Copper |
Compatibility |
Excellent |
Excellent |
Good |
Excellent |
- No liquid containing abrasive stone/grain is allowed
- Please contact us for the use of High Silicon Aluminum
Filtering Performance :
Suction Strainer | 3mm (Solids larger than this must be removed in the tank) |
Filter | 50 m: 95% (specific gravity 2.7) 100 m: 99% (specific gravity 2.7) |
High-efficiency TrochoidTM Pump
YTH-CT uses a TrochoidTM pump which excels in fluid control efficiency. The double-cyclone system sorts out chips and enables direct connection to the coolant tank.
Compatible types of fluid
- Water-soluble coolant fluid
- Not for water-insoluble coolant fluid, lubricant oil or fuel oil
- Not for clear water, purified water, aqueous solutions and viscous fluids without rust-preventive property, corrosive liquid, solvents, and oils
- Relief valve is built into the unit.
Huge Energy Saving Effect Reduces Utility Costs
The use of YTH-CT results in huge energy savings over the conventional centrifugal pumps. The electric power cost is greatly reduced.
- Operating cycle: total 80 seconds cycle
- Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
- Unload (0MPa) 20 sec. Coolant through (1.1 MPa) 20 sec.
- The calculation is based on operation 8hours/day, 365days/year, and the electric power billed at 20/kWh.
Results may differ according to the conventional pump specifications and the machining conditions reference data
Series name | C SERIES CT (Specification : Double cyclone filter + TrochoidTM pump) |
C SERIES CI (Specification: Cyclone filter + Impeller pump) |
||||
Specifications for pump proper | ||||||
Pump model | T208 50Hz / 60Hz |
T216 50Hz / 60Hz |
I155 | I152 | I305 | I302 |
Flow rate (l /min) | 12.0 / 14.4 | 24.0 / 28.8 | 150 (Maximum) | 300 (Maximum) | ||
Compatible fluid | Water-soluble coolant fluid | |||||
Maximum allowable viscosity (mm2/s) (Filtering performance) |
22 | 2 | ||||
Liquid temperature range (oC) | -5 -60 | |||||
Rotational speed (r/min) | 1500 / 1800 | 3000 | 3600 | 3000 | 3600 | |
Maximum pressure (MPa) | 2.0 | – | ||||
Total pump head (m) | – | 55 | 40 | 65 | 45 | |
Filter type | Cyclone x 2 stages | Cyclone x 1 stage | ||||
Filtering performance | 100m: 99.9~ 50 m: 95% (Silica sand: specific gravity2.7) | |||||
Contaminant drain port flow rate (l/min) | 30~40 (Pressure 0.02MPa) |
20~35 (Pressure 0.02MPa) |
25~40 (Pressure 0.02MPa) |
45~60 (Pressure 0.02MPa) |
50~70 (Pressure 0.02MPa) |
|
Remarks | Install a plate filter of #18 or finer mesh on the suction end of the tank. | |||||
Painted color of the pump section | Flat black (Approximately Munsell N1.0) | |||||
Approximate weight (kg) | 16 | 23 | 34 | 33 | ||
Relief valve specifications | ||||||
Type | External return type | – | ||||
Relief pressure setting (MPa) | 2.0 / 1.5 | – | ||||
Motor specifications*1 | ||||||
Model No. | 750A3 | 1500A3 | 1500AC | 3700AC | ||
Specifications | 3-phase, squirrel-cage induction motor, totally enclosed, external fan, flange-mounting configuration | |||||
Output (kW) | 0.75 | 1.5 | 1.5 | 3.7 | ||
Voltage (V) | 200/200/220/230 | 200/200/220/230 | 200/200/220/230 | 200/200/220/230 | ||
Frequency (Hz) | 50/60/60/60 | 50/60/60/60 | 50/60/60/60 | 50/60/60/60 | ||
Rotational speed (r/min) | 1440/1730/1745/1745 | 1445/1740/1750/1755 | 2890/3460/3485/3495 | 2910/3490/3515/3525 | ||
Rating | S1 | |||||
Current (A) | 3.80/3.40/3.40/3.40 | 6.80/6.40/6.00/6.00 | 6.00/5.80/5.40/5.20 | 13.6/13.2/12.2/11.8 | ||
Number of phases | 3 | |||||
Number of poles | 4P | 2P | ||||
Insulation class | F | |||||
Approximate weight (kg) | 18 | 23 | 20 | 36 | ||
Protection rating | IP55 | |||||
Efficiency class | IE3 | |||||
Compliance CE | 0 |